edge-host: open3e round 5 — heating-circuit DIDs (stacked on #97) #98

Merged
k.renner merged 1 commits from open3e-round5 into master 2026-07-02 14:39:05 +00:00
Owner

Stacked on #97 (merge that first). Adds the last missing read DIDs: circuit 2/3 supply + room temps, circuit pumps, operation states (frost protection lives in these enums), DHW setpoint. Counterpart HA package PR follows.

🤖 Generated with Claude Code

Stacked on #97 (merge that first). Adds the last missing read DIDs: circuit 2/3 supply + room temps, circuit pumps, operation states (frost protection lives in these enums), DHW setpoint. Counterpart HA package PR follows. 🤖 Generated with [Claude Code](https://claude.com/claude-code)
k.renner added 2 commits 2026-07-02 14:31:06 +00:00
networkd fails the entire can0 configuration on the unsupported option
("Device doesn't support restart from Bus Off") and never raises the
link — found by the reboot test; this, not a socket race, was also the
afternoon's "off (failed)". Bus-off recovery falls to open3e's service
restart loop.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Adds circuits 2/3 (the configured ones on this Vitocal — Mixer One is
absent): supply temps 286/288, room temps 335/336 (radio room sensor
values as seen by the ECU), circuit pumps 402/403, operation states
1416/1417 (incl. frost-protection program state), DHW setpoint 396.
Closes the last cloud read dependencies (ViCare Vitodens entities are
unused clutter; everything actively referenced becomes local).

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
k.renner merged commit d923ef1a80 into master 2026-07-02 14:39:05 +00:00