feat(ntp): extend NTP roles to edge-1, restore keepalived-ntp #315

Merged
k.renner merged 3 commits from claude-bot/ntp-edge-1 into master 2026-07-19 20:05:44 +00:00
Member

Why

The three PVE hosts currently serve NTP to ~150 LAN clients: chrony with allow 10.2.0.0/16 on each, keepalived holding VIP 10.2.40.4, handed to clients by UniFi DHCP option 42 on VLAN 40. Talos can run neither daemon, so the planned bare-metal migration deletes this role outright.

There is a bootstrap circularity to avoid here. talosctl get timeserverspec on k8s-2 returns timeServers: [10.2.40.4], layer: operator — the Talos nodes learn NTP from DHCP, and there is no machine.time block anywhere in the repo. So the cluster's time source is a VIP that only exists because of the hypervisors being retired, and Talos gates boot on time sync. The time source has to be on the LAN (not public internet, which fails during a WAN outage) and outside the cluster (not an in-cluster pod, which cannot come up before etcd). edge-1 satisfies both.

What

chrony-ntp-server gains Debian/Arch support. Three things differ and each would have broken on edge-1:

Debian (PVE) Arch (edge-1)
config path /etc/chrony/chrony.conf /etc/chrony.conf
unit name chrony chronyd
service user _chrony chrony

Arch also ships no /var/lib/chrony or /var/log/chrony, deferring them to tmpfiles.d; the role now creates them explicitly rather than depending on pacman hook ordering. systemd-timesyncd is stopped where present — edge-1 runs it today and it contends with chrony for the clock.

keepalived-ntp is restored. install-ntp-ha.yml referenced it but the role was absent from master, so the playbook could not resolve at all. Recovered from the homelab-migration-summary worktree with three fixes:

  • The health check hardcoded systemctl is-active chrony. On Arch that unit does not exist, so every check fails, parking the host in permanent FAULT so it never takes the VIP. This would have surfaced only at cutover, with the PVE nodes already gone. Unit name is now templated.
  • Install branches on os_family. Unlike chrony, config path and unit name are identical across distros here, so nothing else changed.
  • The sysctl list is now a variable. It unconditionally set net.ipv4.ip_forward=1 — correct on the hypervisors, but on edge-1 it would route between IoT VLAN 30 and service VLAN 40 once the tagged interface exists, bypassing the UDM's inter-VLAN policy. edge_host keeps only ip_nonlocal_bind; VRRP does not need forwarding.

Scope of the two roles

Deliberately different, and this is the main thing to review:

  • chrony runs everywhere. edge-1 serves from its VLAN 30 address (10.2.30.108); allow 10.2.0.0/16 plus inter-VLAN routing covers every client. No network reconfiguration, so this lands as a working second NTP server today.
  • keepalived is gated on ntp_keepalived_enabled, currently false for edge-1. VRRP needs layer-2 adjacency on VLAN 40 and the host has no enp1s0.40 — the switch port now permits the VLAN, but /etc/systemd/network/ has no matching .netdev/.network pair.

edge-1's keepalived priority is 70, the lowest, so it stays BACKUP while the PVE nodes exist and wins the VIP by default once they are gone — no config change at cutover.

Verified

  • Playbook syntax-checks clean (it did not before — the missing role).
  • ntp_cluster resolves to jupiter, neptune, saturn, edge-1.
  • Arch paths, unit name, and absent /var dirs confirmed against the package file list, not assumed.

Not verified — please read before merging

  • Not run against any host. edge-1 was unreachable during this work (unrelated: a UDM IPS block on the workstation, self-inflicted by bursted SSH — the host itself was never touched).
  • Runtime var resolution unverified — ansible-inventory needs the vault password for edge_host/vault.yml.
  • Adding enp1s0.40 is a separate, riskier step. 20-wired.network matches Type=ether broadly and the box is headless; worth doing with console access.
  • keepalived_ntp_auth_pass is plaintext and unvaulted (carried over as-is). VRRP PASS auth crosses the segment in the clear regardless, so vaulting is cosmetic — flagging rather than silently carrying it.
  • Deployment path is unclear. The homelab-migration-summary worktree's CLAUDE.md mandates CI-only execution, but there is no NTP pipeline in .woodpecker/ and the master checkout has no CLAUDE.md at all. If the CI-only rule stands, a pipeline is needed.
## Why The three PVE hosts currently serve NTP to ~150 LAN clients: chrony with `allow 10.2.0.0/16` on each, keepalived holding VIP `10.2.40.4`, handed to clients by UniFi DHCP option 42 on VLAN 40. Talos can run neither daemon, so the planned bare-metal migration deletes this role outright. There is a bootstrap circularity to avoid here. `talosctl get timeserverspec` on k8s-2 returns `timeServers: [10.2.40.4], layer: operator` — the Talos nodes learn NTP from DHCP, and there is no `machine.time` block anywhere in the repo. So the cluster's time source is a VIP that only exists because of the hypervisors being retired, and Talos gates boot on time sync. The time source has to be on the LAN (not public internet, which fails during a WAN outage) **and** outside the cluster (not an in-cluster pod, which cannot come up before etcd). edge-1 satisfies both. ## What **`chrony-ntp-server` gains Debian/Arch support.** Three things differ and each would have broken on edge-1: | | Debian (PVE) | Arch (edge-1) | |---|---|---| | config path | `/etc/chrony/chrony.conf` | `/etc/chrony.conf` | | unit name | `chrony` | `chronyd` | | service user | `_chrony` | `chrony` | Arch also ships no `/var/lib/chrony` or `/var/log/chrony`, deferring them to `tmpfiles.d`; the role now creates them explicitly rather than depending on pacman hook ordering. `systemd-timesyncd` is stopped where present — edge-1 runs it today and it contends with chrony for the clock. **`keepalived-ntp` is restored.** `install-ntp-ha.yml` referenced it but the role was absent from `master`, so the playbook could not resolve at all. Recovered from the `homelab-migration-summary` worktree with three fixes: - **The health check hardcoded `systemctl is-active chrony`.** On Arch that unit does not exist, so every check fails, parking the host in permanent FAULT so it never takes the VIP. This would have surfaced only at cutover, with the PVE nodes already gone. Unit name is now templated. - **Install branches on `os_family`.** Unlike chrony, config path and unit name are identical across distros here, so nothing else changed. - **The sysctl list is now a variable.** It unconditionally set `net.ipv4.ip_forward=1` — correct on the hypervisors, but on edge-1 it would route between IoT VLAN 30 and service VLAN 40 once the tagged interface exists, bypassing the UDM's inter-VLAN policy. `edge_host` keeps only `ip_nonlocal_bind`; VRRP does not need forwarding. ## Scope of the two roles Deliberately different, and this is the main thing to review: - **chrony runs everywhere.** edge-1 serves from its VLAN 30 address (`10.2.30.108`); `allow 10.2.0.0/16` plus inter-VLAN routing covers every client. No network reconfiguration, so this lands as a working second NTP server today. - **keepalived is gated on `ntp_keepalived_enabled`, currently `false` for edge-1.** VRRP needs layer-2 adjacency on VLAN 40 and the host has no `enp1s0.40` — the switch port now permits the VLAN, but `/etc/systemd/network/` has no matching `.netdev`/`.network` pair. edge-1's keepalived priority is **70**, the lowest, so it stays BACKUP while the PVE nodes exist and wins the VIP by default once they are gone — no config change at cutover. ## Verified - Playbook syntax-checks clean (it did not before — the missing role). - `ntp_cluster` resolves to jupiter, neptune, saturn, edge-1. - Arch paths, unit name, and absent `/var` dirs confirmed against the package file list, not assumed. ## Not verified — please read before merging - **Not run against any host.** edge-1 was unreachable during this work (unrelated: a UDM IPS block on the workstation, self-inflicted by bursted SSH — the host itself was never touched). - **Runtime var resolution unverified** — `ansible-inventory` needs the vault password for `edge_host/vault.yml`. - **Adding `enp1s0.40` is a separate, riskier step.** `20-wired.network` matches `Type=ether` broadly and the box is headless; worth doing with console access. - **`keepalived_ntp_auth_pass` is plaintext and unvaulted** (carried over as-is). VRRP PASS auth crosses the segment in the clear regardless, so vaulting is cosmetic — flagging rather than silently carrying it. - **Deployment path is unclear.** The `homelab-migration-summary` worktree's CLAUDE.md mandates CI-only execution, but there is no NTP pipeline in `.woodpecker/` and the `master` checkout has no CLAUDE.md at all. If the CI-only rule stands, a pipeline is needed.
claude-bot added 1 commit 2026-07-19 19:27:35 +00:00
The three PVE hosts currently serve NTP to ~150 LAN clients via chrony with
keepalived holding VIP 10.2.40.4, handed out by UniFi DHCP option 42. Talos
cannot run either daemon, so the planned bare-metal migration removes this
role entirely. edge-1 is brought into the NTP group to take it over.

chrony-ntp-server gains Debian/Arch support. The two distros differ in three
ways that would each have broken on edge-1: config path (/etc/chrony/chrony.conf
vs /etc/chrony.conf), unit name (chrony vs chronyd), and service user (_chrony
vs chrony). Arch also ships no /var/lib/chrony or /var/log/chrony, deferring
them to tmpfiles.d, so the role now creates them explicitly rather than relying
on pacman hook ordering. systemd-timesyncd is stopped where present, since
edge-1 runs it today and it contends with chrony for the clock.

keepalived-ntp is restored -- install-ntp-ha.yml referenced it but the role was
absent from master, so the playbook could not resolve. Recovered from the
homelab-migration-summary worktree with three fixes:

  - The health check hardcoded `systemctl is-active chrony`. On Arch that unit
    does not exist, so every check would fail, parking the host in permanent
    FAULT so it never takes the VIP -- surfacing only at cutover, once the PVE
    nodes were already gone. The unit name is now templated.
  - Install branches on os_family. Config path and unit name are identical
    across distros here, unlike chrony, so nothing else needed changing.
  - The sysctl list is now a variable. It unconditionally set
    net.ipv4.ip_forward=1, which is correct on the hypervisors but would make
    edge-1 a router between IoT VLAN 30 and service VLAN 40 once the tagged
    interface exists, bypassing the UDM's inter-VLAN policy. edge_host keeps
    only ip_nonlocal_bind; VRRP does not need forwarding.

The two roles have different reach by design. chrony runs everywhere: edge-1
serves from its VLAN 30 address (10.2.30.108) and `allow 10.2.0.0/16` plus
inter-VLAN routing covers every client, so no network reconfiguration is
needed. keepalived is gated on ntp_keepalived_enabled, currently false for
edge-1, because VRRP needs layer-2 adjacency on VLAN 40 and the host has no
enp1s0.40 yet -- the switch port permits the VLAN but /etc/systemd/network/
has no matching .netdev/.network pair.

edge-1's keepalived priority is 70, the lowest, so it stays BACKUP while the
PVE nodes exist and wins the VIP by default once they are gone, with no
config change at cutover.

Verified: playbook syntax-checks; ntp_cluster resolves to the four hosts;
Arch paths confirmed against the package file list. Not yet run against any
host, and runtime var resolution is unverified (needs the vault password).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Author
Member

Applied to edge-1 and verified. Updates the "not verified" section of the description.

Dry run — jupiter (regression check, the one that mattered): ok=18 changed=1 failed=0. chrony.conf, keepalived.conf and the sysctl entries all report ok, not changed — the refactor is byte-identical on Debian, so no chrony restart on the production NTP servers. The single change is the health-check script, and its diff is comments plus one log-message capitalization; the functional line still renders systemctl is-active --quiet chrony on Debian. No handler fires on that task, so keepalived is not restarted either. That the live files match the recovered role is also good evidence this really is the role that deployed.

Dry run — edge-1: ok=7 changed=4 failed=1. The failure is a check-mode artifact: the package is not really installed in check mode, so the chronyd unit does not exist yet for the enable/start task. Same for the failed to look up user chrony warnings — the sysusers entry is created by the package install. Both resolve in a real run, confirmed below. Worth noting the dry run cannot fully validate this path on a host where chrony is absent.

Applied to edge-1: ok=14 changed=6 failed=0. All keepalived tasks correctly skipped via ntp_keepalived_enabled: false.

Verified live on edge-1:

  • chronyd active and enabled; systemd-timesyncd inactive
  • listening on 0.0.0.0:123
  • synced to ptbtime1.ptb.de, stratum 2 (it sits at its own local stratum 10 for the first ~minute before converging — worth knowing so a check straight after apply is not misread as a failure)
  • chronyc clients empty, as expected: DHCP option 42 still points at 10.2.40.4

Group vars confirmed resolving on the host: hwts=False, keepalived_enabled=False, iface=enp1s0.40, and sysctl carrying only ip_nonlocal_bind with ip_forward dropped.

Still outstanding: the PVE nodes have NOT been applied — the only delta there is the cosmetic health-check rewrite, which is not worth touching production NTP for 150 clients on its own; it will ride along with the next real run. enp1s0.40 and enabling keepalived on edge-1 remain a separate step.

Unrelated pre-existing bug noticed: ansible/inventory/api.proxmox.yaml fails to parse on every run (Invalid host pattern 'plugin:'), so the dynamic Proxmox inventory is silently not loading.

Applied to edge-1 and verified. Updates the "not verified" section of the description. **Dry run — jupiter (regression check, the one that mattered):** `ok=18 changed=1 failed=0`. `chrony.conf`, `keepalived.conf` and the sysctl entries all report **ok, not changed** — the refactor is byte-identical on Debian, so no chrony restart on the production NTP servers. The single change is the health-check script, and its diff is comments plus one log-message capitalization; the functional line still renders `systemctl is-active --quiet chrony` on Debian. No handler fires on that task, so keepalived is not restarted either. That the live files match the recovered role is also good evidence this really is the role that deployed. **Dry run — edge-1:** `ok=7 changed=4 failed=1`. The failure is a check-mode artifact: the package is not really installed in check mode, so the `chronyd` unit does not exist yet for the enable/start task. Same for the `failed to look up user chrony` warnings — the sysusers entry is created by the package install. Both resolve in a real run, confirmed below. Worth noting the dry run cannot fully validate this path on a host where chrony is absent. **Applied to edge-1:** `ok=14 changed=6 failed=0`. All keepalived tasks correctly skipped via `ntp_keepalived_enabled: false`. Verified live on edge-1: - `chronyd` active and enabled; `systemd-timesyncd` inactive - listening on `0.0.0.0:123` - synced to `ptbtime1.ptb.de`, **stratum 2** (it sits at its own `local stratum 10` for the first ~minute before converging — worth knowing so a check straight after apply is not misread as a failure) - `chronyc clients` empty, as expected: DHCP option 42 still points at `10.2.40.4` Group vars confirmed resolving on the host: `hwts=False`, `keepalived_enabled=False`, `iface=enp1s0.40`, and sysctl carrying only `ip_nonlocal_bind` with `ip_forward` dropped. **Still outstanding:** the PVE nodes have NOT been applied — the only delta there is the cosmetic health-check rewrite, which is not worth touching production NTP for 150 clients on its own; it will ride along with the next real run. `enp1s0.40` and enabling keepalived on edge-1 remain a separate step. **Unrelated pre-existing bug noticed:** `ansible/inventory/api.proxmox.yaml` fails to parse on every run (`Invalid host pattern 'plugin:'`), so the dynamic Proxmox inventory is silently not loading.
claude-bot added 1 commit 2026-07-19 19:44:17 +00:00
Prerequisite for enabling keepalived on edge-1: VRRP needs layer-2 adjacency
with the other NTP members on the service VLAN, and the host has only untagged
VLAN 30. The switch port already permits VLAN 40.

Built to be additive and revertible, because enp1s0 is this headless host's
only path to the network:

  - The parent's 20-wired.network is not edited. The VLAN is attached through
    a 20-wired.network.d/ drop-in instead, so reverting is deleting three paths.
  - The VLAN .network sorts before 20-wired.network and matches explicitly on
    Name=. 20-wired.network matches broadly on Type=ether; a VLAN link types as
    'vlan' rather than 'ether' (confirmed against networkctl output) so it
    should not match anyway, but ordering makes that belt-and-braces.
  - UseRoutes, UseDNS, UseNTP and IPv6AcceptRA are all disabled on the VLAN.
    Taking a second default route and DNS from the VLAN 40 lease would make
    return traffic asymmetric across the two VLANs; untagged VLAN 30 stays the
    only default route.

Tasks are tagged vlan40 so they can be applied without running the whole
edge-host role, which would restart the Z-Wave, open3e and alloy services.

Reconfiguring the parent link is what materialises the VLAN child -- a bare
networkctl reload leaves existing links untouched -- so the handler does that
explicitly. That re-runs DHCP on enp1s0 and is the one genuinely risky step;
worth running with console access to hand.

Not yet applied: the apply was blocked pending authorisation, so edge-1 remains
in its original network state with only 20-wired.network and 80-can0.network.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
claude-bot added 1 commit 2026-07-19 19:50:16 +00:00
The VLAN 40 prerequisite is now in place and verified: enp1s0.40 is up with a
DHCP lease of 10.2.40.153/24, and both jupiter (10.2.40.201) and the VIP
(10.2.40.4) answer at ~0.5ms over that interface, confirming layer-2 adjacency
with the existing VRRP members.

NOT APPLIED. The playbook run was blocked pending authorisation, so edge-1
currently has chronyd active and serving but keepalived not installed and the
VIP not held. Applying this flag is what actually joins the VRRP group.

Expected on apply: edge-1 comes up BACKUP at priority 70, below neptune's 80,
so the VIP stays with jupiter. The failure mode to watch for is edge-1 not
seeing the existing advertisements, concluding it is alone, and claiming
10.2.40.4 -- a duplicate holder of the address ~150 clients use. Verify
immediately after applying that edge-1 is BACKUP and does not hold the VIP,
and stop keepalived if it does.

Co-Authored-By: Claude Bot <claude-bot@renner.uno>
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Author
Member

Fully applied and verified across all four hosts. Supersedes the "not applied" caveats in the description and the earlier comment.

host role keepalived chrony unit clients
jupiter holds VIP 10.2.40.4 active chrony 177
saturn backup (90) active chrony 34
neptune backup (80) active chrony 7
edge-1 backup (70) active chronyd 0

PVE nodes: changed=1 failed=0 on each, exactly as the dry run predicted — only the health-check script, which has no handler, so neither chrony nor keepalived restarted. The VIP never moved and client service was uninterrupted throughout. Applied to a BACKUP node first, then the remaining two.

edge-1: ok=22 changed=7 failed=0. Joined the VRRP group and transitioned to BACKUP at 21:58:55 per /var/log/keepalived-state.log. It does not hold the VIP, which is correct at priority 70. /var/log/keepalived-ntp-health.log is empty — no failed checks. That empty log is the direct evidence for the health-check fix: with the unit name hardcoded to Debian's chrony, every check would fail on Arch and edge-1 would sit in FAULT instead of BACKUP.

The last row of the table is the whole point of the PR — chrony vs chronyd in the same cluster, handled by the same role.

VLAN 40 on edge-1 (second commit) applied cleanly: enp1s0.40 up as type vlan with lease 10.2.40.153/24. Guards verified — exactly one IPv4 default route (still VLAN 30 via 10.2.30.1), IPv6 default unchanged, no DNS servers on the VLAN link. jupiter and the VIP both answer at ~0.5ms over that interface. An auto-revert timer was armed before the change and disarmed after.

edge-1 upstreams confirmed identical to the PVE nodes: PTB stratum-1 (ptbtime1 preferred) plus de.pool.ntp.org. Currently locked to ptbtime1 at Reach 377, offset -45µs. The local stratum 10 line is what matters for the migration — edge-1 keeps serving from its own clock through a WAN outage, which is why it is a valid time source for Talos where public NTP alone would not be.

Ready to merge. Post-migration behaviour needs no further change: when the PVE nodes are rebuilt as bare-metal Talos, edge-1 is the only remaining VRRP member and takes 10.2.40.4 automatically.

Unrelated pre-existing bug, worth a separate issue: ansible/inventory/api.proxmox.yaml fails to parse on every run (Invalid host pattern 'plugin:'), so the dynamic Proxmox inventory is silently not loading.

**Fully applied and verified across all four hosts.** Supersedes the "not applied" caveats in the description and the earlier comment. | host | role | keepalived | chrony unit | clients | |---|---|---|---|---| | jupiter | **holds VIP 10.2.40.4** | active | `chrony` | 177 | | saturn | backup (90) | active | `chrony` | 34 | | neptune | backup (80) | active | `chrony` | 7 | | edge-1 | backup (70) | active | `chronyd` | 0 | **PVE nodes:** `changed=1 failed=0` on each, exactly as the dry run predicted — only the health-check script, which has no handler, so neither chrony nor keepalived restarted. The VIP never moved and client service was uninterrupted throughout. Applied to a BACKUP node first, then the remaining two. **edge-1:** `ok=22 changed=7 failed=0`. Joined the VRRP group and transitioned to BACKUP at 21:58:55 per `/var/log/keepalived-state.log`. It does **not** hold the VIP, which is correct at priority 70. `/var/log/keepalived-ntp-health.log` is empty — no failed checks. That empty log is the direct evidence for the health-check fix: with the unit name hardcoded to Debian's `chrony`, every check would fail on Arch and edge-1 would sit in FAULT instead of BACKUP. The last row of the table is the whole point of the PR — `chrony` vs `chronyd` in the same cluster, handled by the same role. **VLAN 40 on edge-1** (second commit) applied cleanly: `enp1s0.40` up as type `vlan` with lease 10.2.40.153/24. Guards verified — exactly one IPv4 default route (still VLAN 30 via 10.2.30.1), IPv6 default unchanged, no DNS servers on the VLAN link. jupiter and the VIP both answer at ~0.5ms over that interface. An auto-revert timer was armed before the change and disarmed after. **edge-1 upstreams** confirmed identical to the PVE nodes: PTB stratum-1 (`ptbtime1` preferred) plus `de.pool.ntp.org`. Currently locked to ptbtime1 at `Reach 377`, offset -45µs. The `local stratum 10` line is what matters for the migration — edge-1 keeps serving from its own clock through a WAN outage, which is why it is a valid time source for Talos where public NTP alone would not be. **Ready to merge.** Post-migration behaviour needs no further change: when the PVE nodes are rebuilt as bare-metal Talos, edge-1 is the only remaining VRRP member and takes 10.2.40.4 automatically. **Unrelated pre-existing bug, worth a separate issue:** `ansible/inventory/api.proxmox.yaml` fails to parse on every run (`Invalid host pattern 'plugin:'`), so the dynamic Proxmox inventory is silently not loading.
k.renner merged commit 0ca9635d4b into master 2026-07-19 20:05:44 +00:00