fix(rook-ceph): keep the SAN pool on-link with the node addresses
The pool was 10.99.1.0/24, a separate subnet on the same segment, chosen to avoid carving up a /29 with only three addresses left. That choice would have broken the migration it exists for. OSDs move one at a time, so the cluster runs mixed: an OSD already on the attachment has to reach an OSD still using its node's host address on 10.99.0.x. There is no router on this segment — by design, it carries Ceph-internal traffic and nothing else — so a pool outside the /29 is unreachable from the un-migrated side. The two OSDs would mark each other down, during precisely the window that is supposed to be the safe one. Moves the pool into 10.99.0.0/29 with range_start/range_end reserving .4-.6, leaving .1-.3 to the nodes. That is one address per OSD with nothing spare, which is sufficient rather than merely tolerable: osdMaxUpdatesInParallel bounds the migration to one OSD at a time, so allocations grow 1, 2, 3 and never overlap. Headroom returns after the switch is confirmed and the node addresses come out of the Talos configs — then the pool takes the whole /29. Verified: the embedded CNI JSON parses with the intended range and bounds; the NAD passes a server-side dry run. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -29,13 +29,20 @@
|
||||
# needed — unlike the v30iot attachments, there is no DHCP-supplied default
|
||||
# route to confine, because there is no DHCP and no default route.
|
||||
#
|
||||
# A separate subnet from the node addresses. The nodes hold 10.99.0.1-.3/29
|
||||
# for as long as Ceph still uses host networking. OSDs never need to reach
|
||||
# those — the cluster network is OSD-to-OSD — so this pool sits in its own
|
||||
# range on the same segment instead of carving up a /29 that has exactly
|
||||
# three addresses left. Once the provider switch is confirmed, the node
|
||||
# addresses on VLAN 49 have no remaining purpose and can be removed from
|
||||
# the Talos configs.
|
||||
# The pool stays inside 10.99.0.0/29, on-link with the node addresses, and
|
||||
# this is load-bearing during the migration rather than a detail. OSDs move
|
||||
# one at a time, so the cluster runs mixed for a while: an OSD already on
|
||||
# this attachment has to reach an OSD still using the node's host address.
|
||||
# There is no router on this segment, so anything outside the /29 would be
|
||||
# unreachable from the un-migrated side and the two would mark each other
|
||||
# down — during precisely the window that is supposed to be safe.
|
||||
#
|
||||
# range_start/range_end reserve .4-.6 and leave .1-.3 to the nodes. That is
|
||||
# exactly one address per OSD with nothing spare, which is sufficient
|
||||
# because osdMaxUpdatesInParallel bounds the migration to one OSD at a
|
||||
# time: allocations grow 1, 2, 3 and never overlap. Once the switch is
|
||||
# confirmed and the node addresses come out of the Talos configs, the pool
|
||||
# can take the whole /29 and the spare returns.
|
||||
#
|
||||
# IPAM
|
||||
#
|
||||
@@ -44,10 +51,6 @@
|
||||
# with no cluster-wide coordination, so two nodes would hand out the same
|
||||
# address on shared L2. See infrastructure/multus/whereabouts-daemonset.yaml.
|
||||
#
|
||||
# A /24 for three addresses is not extravagance — nothing else can ever live
|
||||
# on this segment to be crowded by it, and it removes address count as a
|
||||
# consideration when OSDs are added later.
|
||||
#
|
||||
# MTU 9000 matches the link. macvlan children inherit the master's MTU, but
|
||||
# it is stated so that a change to the parent does not silently halve
|
||||
# replication throughput without anything in the tree recording the
|
||||
@@ -72,6 +75,8 @@ spec:
|
||||
"mtu": 9000,
|
||||
"ipam": {
|
||||
"type": "whereabouts",
|
||||
"range": "10.99.1.0/24"
|
||||
"range": "10.99.0.0/29",
|
||||
"range_start": "10.99.0.4",
|
||||
"range_end": "10.99.0.6"
|
||||
}
|
||||
}
|
||||
|
||||